The Cleo is a new and intuitive approach to patient vital signs measurement. The Cleo can be configured to measure any combination of: non-invasive blood pressure, SpO2, rapid temperature, and capnography (EtCO2). |
|
Weighing in at less than 3 LBS the portable Cleo is well suited for any patient care area by offering a multitude of vital sign combinations. The Cleo can be used as a basic pulse oximeter or configured to a NIPB/SpO2/Temp spot check monitor. Cleo can also be configured to be a stand-alone capnography or combination capnography/SpO2/NIPB monitor. The Cleo is well suited for both bed side and mobile spot check use. |
|
Specifications: |
Neonatal, pediatric and adult patients |
|
PHYSICAL DIMENSIONS & WEIGHT : |
Base Unit: 8 x 4.5 x 4 (HxWxD inches) |
Weight: 2.5 LBS |
|
PERFORMANCE SPECIFICATIONS: |
Display: 5.0 inch (Diagonal) color TFT |
Resolution: 800 × 3(RGB) × 480 |
Trace: 2 waveforms |
Waveforms: PLETH, ETCO2 |
Indicator: Alarm Indicator |
Power indicator |
Pulse beep and alarm sound |
Trend time: From 1 to 72 hours |
NIBP |
Measuring Technology: Automatic oscillating measurement |
Cuff Inflating: <30s (0 ~ 300 mmH, standard adult cuff) |
Measuring Period: AVE<40s |
Mode: Manual, Auto, STAT |
|
Measuring Interval: |
in AUTO Mode: 2 min ~ 4 hrs |
Pulse Rate Range: 30 bpm ~ 250 bpm |
Measuring Range: Adult/Pediatric Mode |
SYS: 40 ~ 250 (mmHg) |
DIA: 15 ~ 200 (mmHg) |
|
Neonatal Mode: |
SYS: 40 ~ 135 (mmHg) |
DIA: 15 ~ 100 (mmHg) |
Resolution: 1mmHg |
Pressure Accuracy: Maximum Mean error: ±5mmHg |
Maximum Standard |
deviation: 8mmHg |
Overpressure Protection: Adult Mode: 280(mmHg) |
Neonatal Mode: 150 (mmHg) |
Alarm Limit: SYS: 50 ~ 240 mmHg |
DIA: 15 ~ 180 mmHg |
Standards: Meets performance standards of |
ANSI/AAMI SP10:2002 |
SPO2 |
ASpO2: Anti-motion SpO2 |
SpO2% Range: 0 ~ 100% |
SpO2 Accuracy: ±2% (70 ~ 100%,non-motion) |
±3% (70 ~ 100%, motion) |
Pulse Rate Range: 30-250 bpm |
Pulse Rate Accuracy: ±2 bpm(non-motion), |
±3 bpm (motion) |
Alarm Upper-lower Limit: Upper limit 70 ~ 100%, |
Lower limit 70 ~ 100% |
SpO2 Probe: Red light LED wavelength |
660nm±5nm |
Infrared light LED wavelength: |
940nm±10nm |
Standards: Meets performance standards |
of EN ISO 9919:2005 |
RAPID TEMPERATURE (OPTION) |
|
Temperature: |
Seconds, 2 “beeps” at 30 seconds, |
1 “beep” at 45 seconds, and 2 |
“beeps”at 60 seconds |
Patient Accuracy: A Standard Prediction Mode reading |
and a Direct Mode reading will differ |
by less than ±0.2°C (±0.4°F) on 98% |
of tested patients |
Batteries: Four “AA” Required. |
Standard IEC package size. |
Alkaline --1.5 Volt |
Approx. 6000 temperature readings |
EtCO2 (OPTION) |
Mode of Sampling: Sidestream or Mainstream |
Principle of Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts. |
CO2 measurement Range: 0 to 150 mmHg breath |
|
Response Time:: |
<3 seconds - includes transport time and rise time |
Inspired CO2 |
measurement Range: 3 ~ 50 mmHg |
Standards: Meets performance standards of ISO/ |
|